Discarding Criteria

Product information

Elevator ropes are discarded on account of wire breaks, wear and/or diameter reduction.
During evaluation, corrosion, rope deformation or excessive elongation should also be taken account.

Technical data sheet Make contact


Technical data

rope specifications rope-Ø Number of load bearing wires Rope class Case 1* Case 2* Case 3* Case 4* Case 1** Case 2** Case 3** Case 4**
F819 S-FC 152 8 x 19 >15 >8 ≤4 ≤1 >30 >10 >4 >1
F819 W-FC 152 8 x 19 >15 >8 4 1 >30 >10 4 1
F819 S-FC DT 152 8 x 19 >15 >8 4 1 >30 >10 4 1
PAWO F3 6,5mm
7 - 20mm
114
152
6 x 19
8 x 19
>12
>15
>6
>8
4
4
1
1
>24
>30
>8
>10
4
4
1
1
PAWO F7 152 8 x 19 >15 >8 4 1 >30 >10 4 1
PAWO F7S 152 8 x 19 >15 >8 4 1 >30 >10 4 1
PAWO F10 8-12mm
13-20mm
117
144
9 x 13
9 x 16
>12
>14
>6
>8
4
4
1
1
>23
>28
>8
>10
4
4
1
1
PAWO 819W 152 8 x 19 >15 >8 4 1 >30 >10 4 1
PAWO 836WS 288 8 x 36 >24 >12 4 1 >48 >18 4 1
PAWO F4e 152 8 x 19 >15 >8 4 1 >30 >10 4 1
PAWO F5e 114 6 x 19 >12 >6 4 1 >24 >8 4 1
PAWO F1 114
114
152
6 x 19
6 x 19
8 x 19
>12
>12
>15
>6
>6
>8
4
4
4
1
1
1
>24
>24
>30
>8
>8
>10
4
4
4
1
1
1

* Replace ropes or examine within a specified period as stated by an authorised expert
**Discard rope immediately
Case 1 Broken wires randomly distributed among other strands per rope lay
Case 2 Broken wires predominating in one or two outer strands per rope lay
Case 3 Adjacent broken wires in one outer strand
Case 4 Valley breaks pe rope lay

The length of one rope lay is approxymately equivalent to 6 x d (where d is the nominal rope diamater)